** The version of this file is 3.3.0.2

This file includes important information for users who wish to configure and use Bosch video recorders within LenelS2 OnGuard access control software.

A) SYSTEM COMPATIBILITY

This section lists the latest builds of system components which have been successfully tested by Bosch.

OnGuard:						7.6.382.271
OnGuard 7.6 Accessory Add-On for Bosch Video Recorder	1.0.2 
BoschVsdkTranslator.dll:				3.3.0.2
IppIntegrator.dll:					4.1.0.2
rcpp4.dll:						5.1.0.31
IntegrationConfig.dll:					3.3.0.1
Bosch Video SDK:					6.32.00.99
Bosch Integration Configurator:				2.2.0.1
Video Recording Manager (VRM):				4.00
Client Operating System:				Microsoft Windows 10 Professional
Server Operating System:				Microsoft Windows Server 2016 , Microsoft Windows Server 2012


B) CONFIGURATION

This section describes the steps needed to configure the Lenel OnGuard system to interface with Bosch video recorders.

1. Setup the OnGuard system as normal per the instructions from LenelS2.

2. Setup the Bosch Video Recorder(s) per the instructions from Bosch and confirm, using the included client software, that live and playback video are    working correctly.

3. If not already installed, install the Microsoft Visual C++ 2017 Redistributable on all clients and servers where the "Bosch Video Recorder" accessory add-on will be installed.

4. In the Accessory Add-On package goto the prerequisites folder and install the Bosch Video SDK (VideoSDK.06.32.0099.x86.msi) on all workstations (clients    and servers) in Administrator mode. The Bosch Video SDK version that has been tested with OnGuard is included in the accessory add-on package.

NOTE: If there is already a version of the Bosch Video SDK software from a previous installation, please uninstall the previous version before installing the new Bosch Video SDK software found in the accessory add-on package.

5. Install the OnGuard Accessory Add-On (setup.exe) on all workstations (clients and servers) in Administrator mode (Right click on setup.exe and click "Run as administrator").

6.In the Accessory Add-On package goto to prerequisites folder and install the Bosch Integration Configurator application   (BoschIntegrationConfiguratorSetup.msi) on any one of the OnGuard PCs (clients/server). Please note that the Bosch Integration Configurator tool can be installed on any OnGuard PC to generate the device configuration file as explained in setup 7.

NOTE: If there is already a version of the Bosch Integration Configurator software from a previous installation, please uninstall the previous version before installing the new Bosch Integration Configurator found in the accessory add-on package. Also please refer to the Pre-requisite section in the Bosch Integration Configurator.pdf user guide for all the software packages that must be installed prior to installing Bosch Integration Configurator.

7.Using Bosch Integration Configurator tool create and save the “BoschVsdkTranslatorConfig.xml” device configuration file. Please refer to the Bosch Integration Configurator User Guide.pdf document for the device configuration details and also generating the device configuration file. The user guide is under the prerequisites folder in the accessory add-on package.

NOTE: The device configuration file name must be saved as “BoschVsdkTranslatorConfig.xml”. 

8. Copy “BoschVsdkTranslatorConfig.xml” file into the OnGuard installation folder (typically "C:\Program Files(x86)\OnGuard") on all workstations (clients and servers). NOTE: This file must be an exact copy on all workstations

9. Run OnGuard's System Administration application and select the "Video/Digital Video" menu item. On the "Video Recorder" tab click the "Add" button and    perform the following steps for each Bosch video recorder:
   	- Select "Bosch Video Recorder" in the type drop-down
   	- Enter the recorder's name and IP address
   	- Enter the OnGuard server name
   	- Click "OK"
   	- Follow the prompts as is normal for OnGuard

10. In System Administration application right click on the Bosch recorder item that was added in the previous step and select “Import From Recorder” to import the required cameras associated with the Bosch recorder into the OnGuard system. 

11. Click on the “Display Video” checkbox to display the video and verify the camera and recorder are configured properly. 


C) LIMITATIONS

This section lists known limitations.

- Camera Resolution cannot be configured from OnGuard System Administration
- Activate Digital PTZ (Digital Zoom) is not supported for Live or Recorded Video in this integration
- The playback speed of recorded video is not correctly displayed or not displayed at all for recorded video from cameras configured to the the VRM v4.0       recorders (DIVAR IP x000).
- When the LS Communication Service is stopped,  there is no Communication Lost event for the recorder The recorder and cameras are displayed in the System     Status tree properly as offline.
- When exporting video from the DIVAR IP 5000 in OnGuard using the MPEG-ActiveX selection, the output mpg file could not be played back using Media Player   of VLC.
- Failover is not supported in the OnGuard integration  the VRM v4.0  recorders (DIVAR IP x000).
- Framerate is not configurable for cameras configured to the  VRM v4.0  recorders (DIVAR IP x000).
- The Relay Outputs and Alarm Inputs of the VRM v4.0 recorders (DIVAR IP x000) are not supported in OnGuard.
- The Click-To -Center feature is not supported for cameras configured to the VRM v4.0  recorders (DIVAR IP x000).
- The Auto Focus and Auto Iris PTZ functions are not supported for cameras configured to the VRM v4.0  recorders (DIVAR IP x000) recorders.
- Client Side PTZ Presets are not supported for PTZ cameras configured to the VRM v4.0  recorders (DIVAR IP x000) recorders.
- With HD cameras  in matrix/template mode, it is recommended that a maximum of 4 recorded video streams be displayed at once. To display an additional       recorded video, close the matrix window and re-open a video player  for the desired camera.
- For Web VideoViewer to display video from VRM v4.0  recorders (DIVAR IP x000) recorders, copy the BoschVsdkTranslatorConfig.xml file from the OnGuard      directory to program folder for the web browser being used, e.g., Program Files\Internet Explorer.